192 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix B Command Descriptions and Communications Interface
CLI Commands
Example 2:
To set the cable advance for Port 5 to Manual, with a value of 00x01023 -
tc1000>set cable-adv port 5 manual 00:10:23
Remarks: The valid range for the manual cable advance value is from 00:00:00 to
0E:A0:EA.
Related:
show cable-adv
Level : Power-User and Admin only
Caution: Manual cable advance should only be performed in a lab
environment.
Note: If the cable advance is presently valid, then the cable advance
setting is constrained to update at a rate of 26 ps/s, as required by the
DTI specification, in both automatic and manual modes. To make a
large change in the cable advance manually, first disable the port with
the Set Interface command.