200 TimeCreator 1000 User’s Guide 097-93100-01 Revision C – February, 2010
Appendix B Command Descriptions and Communications Interface
CLI Commands
Show EIA-232
This command displays the serial port’s operating parameters: baud rate, parity,
word length, stop bits, and handshaking.
Command Syntax:
show eia-232
Example:
tc1000>show eia-232
Response:
Serial port configuration:
Baud: 9600
Data: 8
Parity: none
Stop: 1
State: enabled
Remarks: The serial interface is fixed at 9600, None, 8, 1, Xon/Xoff. There is no
associated set command. The EIA-232 interface can be enabled and disabled using
the Set Service command. h
Related:
set resource, show resource
Level : User, Power-User and Admin
Note: 57600 baud rate is supported only in the IMC rev H
version 1.00.13 or below.