HYDRAULICS
4203781 First Edition 6-39
6
16. Calculate right wing cutting unit circuit leakage.
(Step 13 – Step 14 / Step 13 x 100 = Leak
Percentage)
Is right wing cutting unit circuit leakage 10% or
less?
YES The right wing cutting unit circuit is good.
Proceed to “Right Wing Cutting Unit Motors
Test” on page 6-43.
NO Proceed to next question.
Is right wing cutting unit circuit leakage 11% to
20%?
YES The right wing cutting unit circuit is marginal.
Additional testing is required. Proceed to
“Right Wing Cutting Unit Pump Test” on
page 6-39.
NO Proceed to next question.
Is right wing cutting unit circuit leakage 21% or
more?
YES Test individual components in right wing
cutting unit circuit for leakage. Proceed to
“Right Wing Cutting Unit Pump Test” on
page 6-39.
Right Wing Cutting Unit Pump Test
See Figures 6-33 through 6-35.
!
WARNING
1. Park the mower safely. (See “Park Mower Safely” on
page 1-6.)
2. Before performing this test, perform right wing cutting
unit circuit test, leaving flow meter connected as
outlined.
Figure 6-33
Figure 6-34
3. Install blocking disk between hose (1) and tee fitting
(3).
4. Open flow meter valve (2) completely.
The hydraulic system is under pressure, and the
oil will be hot.
Always relieve pressure in the hydraulic
system before performing service.
Failure to follow appropriate safety
precautions may result in death or serious
injury.
Required Tools and Materials
Flow Meter
-10 ORFS Test Hose 3600 psi (207 bar)
-10 ORFS Tee Fitting
-10 ORFS Blocking Disk
TN2237
1
3
TN1363
2