System & Station
Program *60 TBSU/RBSU/RBSS Circuit Operation (NT or TE)
3-112
Strata DK40 Programming Manual Spring 1999
Program *60
TBSU/RBSU/RBSS Circuit Operation (NT or TE)
Program Type:
System
Initialised Default:
RBSU = NT
Program *60 Overview
This programming option is used to select NT or TE operation for each of the circuits on a
TBSU/RBSU unit.
Refer to the legend to which operation mode is available on each of the PCB’s.
Program 61-1
Fault Test Report Destination
Program Type:
System
Initialised Default:
‘0’ No Check
Program 61-1 Overview
This program is for setting the destination for the results of the test when completed.
Option 0: The automatic fault testing will not be run.
Option 1: The system will carry out the test and wait for the information to be received via
the TTY or remotely through the IMDU Modem.
Option 2: The system will carry out the test and report to the SMDR.
(QWHU 3URJ 0RGH 0 6SNU
*
93+ROG 0 6SNU /LQH .H\ 0 +ROG 0 6SNU 6SNU & & +ROG 0 6SNU & & +ROG
Key Line RBSU/RBSS Cct Number LED ON LED OFF
11TENT (Default)
22TENT (Default)
33N/ANT
44N/ANT
Key Line TBSU Cct Number LED ON LED OFF
11TENT (Default)
22TENT (Default)
(QWHU 3URJ 0 RGH 0 6SNU 94+R OG 0 6SNU 4 +ROG 0 6SNU & & +ROG 0 6SNU & & +ROG
Press the Line Key to switch between TE and NT operation
Enter Slot Number
DATA = 0 No check
1 Check and awaiting access via TTY or IMDU
2 Check and report to SMDR