System & Station
Program *63-1 Dialled Sub-Address Timeout
3-122
Strata DK40 Programming Manual Spring 1999
Program *63-1
Dialled Sub-Address Timeout
Program Type:
System
Initialised Default:
04 (4 seconds)
Program *63-1 Overview
The DK40 system will accept Sub-Address information dialled from a DKT/EKT/2 wire
extension, where the destination is an internal ISDN2 extension port. This programming
parameter offers a system “Dialled Sub-Address time-out” facility. Once the DKT/EKT/2
wire extension has dialled a valid extension number the “time-out” is started, any further
digits dialled are interpreted as Sub-Address information. When the time-out expires, the
system considers the dialled Sub-Address as complete and will route the call.
Note
A very short time-out will require users to enter the Sub-Address information very
quickly. Along time-out will increase internal call setup time.
(QWHU 3URJ 0RGH 0 6SNU
*
96+ROG 0 6SNU 40+ROG 0 6SNU & & +ROG 0 6SNU & & +ROG
DATA Timeout Value DATA Timeout Value
00 No Internal Sub-Addressing 06 06 Seconds
01 01 Seconds 07 07 Seconds
02 02 Seconds 08 08 Seconds
03 03 Seconds 09 09 Seconds
04 04 Seconds 10 10 Seconds
05 05 Seconds
DATA = Duration of timeout. See legend below: