Program *12 System Assignments, Basic Timing
System & Station
Strata DK40 Programming Manual Spring 1999
3-31
Program *12
System Assignments, Basic Timing
Program Type:
System
Initialised Default:
Program Timing
Code 1 3
Code 2 1
Code 7 2
Code 8 2
(QWHU 3URJ 0RGH 0 6SNU
*
45+ROG 0 6SNU 00+ROG 0 6SNU & & +ROG 0 6SNU & & +ROG
Program
Code Function Code Time
Required
Code
1
Disconnect
Timer
(TIE Lines Only)
1 20 sec.
2 30 sec.
4 40 sec.
2
Delay Dialling
Timer
(TIE Lines Only)
1 0.2 sec.
2 0.8 sec.
3 1.6 sec.
7
Ring Time
on
DISA Lines
1 120 sec.
2 15 sec.
3 240 sec.
4 30 sec
8
Automatic Release
Timer
(TIE Lines Only)
1 No Automatic Release
2 30 mins.
3 60 mins.
SELECT = 1, 2, 7 or 8
Enter program code, 1, 2, 7 or 8 from table below.
SELECT CODE = Enter required code
for the time listed in the table below.