Encompass 4 Reader System Guide
D-18
ATA operating range set
NN = 00 (shortest) to 1F (longest)
643NN Done
ATA operating range set to
longest range
6431F Done
Automatic periodic RF status
report disable
830 Done
Automatic periodic RF status
report enable
831 Done
Aux info append disable 310 Done
Aux info append enable 311 Done
Basic protocol select 610 Done
Baud rate = 1200 baud set 1002 Done
Baud rate = 19.2 K baud set 1006 Done
Baud rate = 2400 baud set 1003 Done
Baud rate = 38.4 K baud set 1007 Done
Baud rate = 4800 baud set 1004 Done
Baud rate = 9600 baud set 1005 Done
Boot checksum display 543 BCKS xxxx
xxxx = 4-byte ASCII checksum
Buffered handshake report 577 XX = number of handshakes
Comm port parameters display 522 MAIN Bx Sx Px D0
B0 = 110
B1 = 300
B2 = 1200
B3 = 2400
B4 = 4800
B5 = 9600
B6 = 19.2
B7 = 38.4
S0 = one stop bit
S1 = two stop bits
P0 = no parity
P1 = even
P2 = odd
D0 = EOL delay of 0 ms
Table D-3 Encompass 4 Reader Commands Listed Alphabetically (continued)
Command Name Code Reader Message