V2.9.4 EXTPID OUTPUT (ID 86)
This monitoring value shows the output of the PID controller as a percentage (0-100%).
You can give this value to, for example, the analogue output.
V2.9.5 EXTPID STATUS (ID 87)
This monitoring value shows the state of the PID controller.
9.8 MULTI-PUMP
V2.10.1 MOTORS RUNNING (ID 30)
This monitoring value shows the actual number of motors that operate in the Multi-pump
system.
V2.10.2 AUTOCHANGE (ID 1114)
This monitoring value shows the status of the autochange requested.
V2.10.3 NEXT AUTOCHANGE (ID 1503)
This monitoring value shows the time that remains to next autochange.
V2.10.4 OPERATE MODE (ID 1505)
This monitoring value shows the operation mode of the drive in the Multi-pump system.
V2.10.5 MULTI-PUMP STATUS (ID 1628)
This monitoring value shows the status of the drive in the Multi-pump system.
V2.10.6 COMMUNICATION STATUS (ID 1629)
This monitoring value shows status of the communication between the drives in the Multi-
pump system.
V2.10.7 PUMP (1) RUNNING TIME (ID 1620)
This monitoring value shows the operating hours of the pump in Multi-pump system.
V2.10.8 PUMP 2 RUNNING TIME (ID 1621)
This monitoring value shows the operating hours of the pump in Multi-pump system.
V2.10.9 PUMP 3 RUNNING TIME (ID 1622)
This monitoring value shows the operating hours of the pump in Multi-pump system.
V2.10.10 PUMP 4 RUNNING TIME (ID 1623)
This monitoring value shows the operating hours of the pump in Multi-pump system.
VACON · 210 MONITORING VALUE DESCRIPTIONS
9
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/

Table of Contents

Other manuals for Vacon 100 flow

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon 100 flow and is the answer not in the manual?

Vacon 100 flow Specifications

General IconGeneral
Protection classIP20
Communication interfaceRS-485
Operating temperature-10°C to +50°C
Storage temperature-40°C to +70°C
Ambient temperature-10°C to +40°C
Control methodSensorless vector control
Communication protocolsCANopen
ApprovalsCE, UL
I/O2 analog inputs
Protection featuresOvercurrent, overvoltage, undervoltage, overtemperature
Frequency range0 Hz to 400 Hz
Humidity5% to 95%, non-condensing
Voltage range208-240 V