P3.1.4.13.3 TORQUE STABILATOR DAMPING TIME CONSTANT (ID 1413)
Use this parameter to set the damping time constant of the torque stabiliser.
P3.1.4.13.4 TORQUE STABILATOR DAMPING TIME CONSTANT FOR PM MOTORS (ID 1735)
Use this parameter to set the damping time constant of the torque stabiliser for permanent
magnet or reluctance motors.
P3.1.4.13.5 TORQUE STABILATOR FILTER TIME CONSTANT (ID 15650)
Use this parameter to set the lowpass filtering time constant of the torque stabilizer.
P3.1.4.13.6 TORQUE STABILATOR FILTER TIME CONSTANT FOR PM MOTORS (ID 15651)
Use this parameter to set the lowpass filtering time constant of the torque stabilizer for
permanent magnet or reluctance motors.
10.3 START/STOP SETUP
The drive is started and stopped from a control place. Each control place has a different
parameter to select the source of the frequency reference. You must give the start and stop
commands in each control place.
The local control place is always the keypad. With parameter P3.2.1 Remote Control Place
you can select the remote control place (I/O or Fieldbus). The selected control place shows
on the status bar of the keypad.
VACON · 230 PARAMETER DESCRIPTIONS
10
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/

Table of Contents

Other manuals for Vacon 100 flow

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon 100 flow and is the answer not in the manual?

Vacon 100 flow Specifications

General IconGeneral
Protection classIP20
Communication interfaceRS-485
Operating temperature-10°C to +50°C
Storage temperature-40°C to +70°C
Ambient temperature-10°C to +40°C
Control methodSensorless vector control
Communication protocolsCANopen
ApprovalsCE, UL
I/O2 analog inputs
Protection featuresOvercurrent, overvoltage, undervoltage, overtemperature
Frequency range0 Hz to 400 Hz
Humidity5% to 95%, non-condensing
Voltage range208-240 V

Related product manuals