(a) Programming by the SFC
S0
S10
S11
S12
S13
S10
X0
TRAN S10
M0
M1
T0
TRAN S12
T1
TRAN S13
T2
X2
TRAN S10
M9002
SFC
SET S0
S0
T2
X2
TRAN S0
Y0
TRAN S11
PLS
M1
Y1
PLS
M0
X1
SET
Y2
T0
K30
Y3
T1
K50
RST
Y2
T2
K30
When X1=OFF, chosen to execute the “Single Run”
mode, the active step transfers to S0.
108
Ladder
Diagram
in the main
program
Filling_Bottle
Activate the step S0 in the SFC program
The SFC is named Filling_Bottle.
Turn the READY indicator ON.
When X0=ON, the active step transfers to S10.
Drive the conveyor motor to move forward
At the moment that the S10 turns from OFF to ON, the input signal
X1 has been already ON for a while. Thus, pay extra attention to
the X1 signal in order to make the step transfer smooth.
Drive the nozzle lifter to move down.
Activate the coil of 3 second timer.
When the contact T0=ON, the active step transfers to S12.
Drive the valve open to ll up the bottle.
Activate the coil of 5 second timer.
When the contact T1=ON, the active step transfers to S13.
Drive the nozzle lifter to move up.
Activate the coil of 3 second timer.
When X1=ON, chosen to execute the
“Repeat” mode, transfer the active
step transfers to S10.