271
D E N E G P
D
1
2
M
3
○○○
FNC
128
X Y M S
D.b R.b
KnX KnY
KnM KnS
T C
D,R
V,Z
UnG
K,H
E
" $"
D
DENEGP D0
X0
D
○
Operand
Devices
BIN Floating Point Negation
D : the device to be positive/negative inverted
X0=OFF→ON
–123.45
123.45
(D1, D0) BIN floating number
(D1, D0) BIN floating number
Before operation
After operation
D
D
This instruction inverts a BIN oating point format number which is designed by into its negative value and
stores the result back into .
When X0 = “OFF” → “ON”, this instruction performs the positive/negative inversion operation on the BIN oating
point number in (D1, D0), and then the result will be stored back into (D1, D0).
This instruction is a 32-bit instruction. Therefore, be sure to input DENEG or DENEGP in the program.
D
The operand must assign to a BIN oating point number for the calculation.
The format for storing a oating point number will occupy two Registers in the PLC system. Please refer to the
section 2-13 “Numerical System” for the reference of the oating point number.

Table of Contents