WAREMA climatronic
®
Installation Instructions
Factory presets
Light, dimmable
Fan, infinitely variable with fan valve
Fan 6/12 V with fan valve
Fan, infinitely variable, external, with valve
Markisolette
Drop-arm awning
Facade awning
Vertical awning
Internal roller blind
Light, dimmable (external)
Light
Heater
Air conditioner
Fan, infinitely variable (external)
Fan 3 steps
Fan, fan valve
Window
Venetian blind
Pleated blind
Roller shutter
External venetian blind
Conservatory awning
Articulated arm awning
Unit
Setting step
3
3
3
3
3
3
3
3
3
3
1
3
3
3
3
3
3
3
Number of steps
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
%
Maximum step
10
10
10
1
1
1
1
1
10
10
10
10
1
1
1
1
1
1
Min
Step duration
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES/
NO
Active during leave?
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES/
NO
Active during absence?
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Humidity/
temp. 1,2
Inside sensor allocation
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS2
WS3
Outside sensor allocation
Diff. temp. control
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
°C
Limit value diff. temp. ON
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
%
Position diff. temp. ON
+38°
+38°
De-
grees
Slat angle diff. temp. ON
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
°C
Limit value diff. temp. OFF
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
%
Position diff. temp. OFF
-80°
-80°
De-
grees
Slat angle diff. temp. OFF
Rain monitor
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON/
OFF
Rain monitor
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Min
Off delay
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
%
Position PRECIPITATION
-80°
De-
grees
Slat angle PRECIPITATION
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES/
NO
Active during leave?
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES/
NO
Active during absence?
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS1
WS2
WS3
Precipitation sensor allocation
Humidity control
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON/
OFF
Humidity control
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
%RH
Limit value WET
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
%
Position WET
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
%RH
Limit value DRY
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
%
Position DRY
Direct
control with
steps
Direct
control with
steps
Direct
control with
steps
Direct con-
trol
Direct con-
trol
Direct con-
trol
Direct con-
trol
Direct con-
trol
Direct con-
trol
Direct con-
trol
Direct
control with
steps
Direct
control with
steps
Direct con-
trol
Direct
control with
steps
Direct con-
trol
Direct con-
trol
Direct con-
trol
Direct con-
trol
Direct con-
trol
Direct con-
trol
Direct
control with
steps
Mode
3
3
3
3
3
3
3
3
1
1
3
3
1
3
3
3
3
3
3
Number of steps
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
%
Maximum step
10
10
10
1
1
1
1
1
0
0
10
10
10
10
1
1
1
1
1
Min
Step duration
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES/
NO
Active during leave?