890370_0•en•01.06.2009
We reserve the right to carry out improvements
62
WAREMA climatronic
®
Installation Instructions
7.2.5.5 Setting run times and tilting
steps
The run times and tilting steps are set in this menu. The values to be set and,
consequently, the menu lines displayed depend on the product type. We rec-
ommend setting the run times as exactly as possible to ensure that the sun
shading products move to the correct positions. Values typical for the par-
ticular product are already preset at the factory; the presettings are usually
generous, i.e. on the long side:
Turn the function wheel until the parameter to be changed is shown
highlighted in colour. The set value appears on the left, e.g. [02:30] at
[Runtime up mm:ss]. Press the function wheel.
Adjustable values are now displayed in an enlarged format.
Turn the function wheel until the required value is displayed. Press the func-
tion wheel once more to save the value and to jump to the next parameter.
Press the [Next] button after all parameters have been set.
However, if you selected the [Others] external venetian blind type for makes
of other manufacturers, the following window appears, in which you addition-
ally need to set the parameters for slat angle and tilting time.
Please refer to the respective technical documentation of the corresponding
manufacturer for the relevant data.