890370_0•en•01.06.2009
We reserve the right to carry out improvements
18
WAREMA climatronic
®
Installation Instructions
The WAREMA climatronic always logically controls products through chan-
nels. The following product types can presently be activated using the
WAREMA climatronic:
Articulated arm awning Light
Conservatory awning Light, dimmable (external)
External venetian blind Fault alarm contact
Roller shutter Internal roller blind
Pleated blind Vertical awning
Venetian blind Facade awning
Window Drop arm awning
Fan, fan valve Markisolette
Fan 3 steps Fan, infinitely variable (external) with fan valve
Fan, infinitely variable (external) Fan 6/12 V with fan valve
Air conditioner Fan, infinitely variable with fan valve
Heater Light, dimmable
A product is connected directly to the outputs of a switch actuator of the
WAREMA climatronic. It requires one to three switching outputs; for example,
sun shading products require two switching outputs for raising and lowering,
a light requires only one switching output for switch-on and switch-off.
3.3.3 Groups
If you want to manually activate several channels together, they can be com-
bined into a group. You can then, for example, raise or lower the conserva-
tory awning and the external venetian blind of a conservatory together.
Up to 32 channels can be allocated to one group.
NOTE The group adopts the product properties of the first allocated channel; if
this is a roller shutter, for example, then the operating behaviour of the group
corresponds to that of a roller shutter even if other slat products, lights or cli-
mate control products belong to this group.
Of course, channels with identical products can also be combined to a
group. For example, if you have created a channel 1 for the roller shutters
of each room, then all roller shutters of the building can be combined to a
group and moved at the same time.
A maximum of 32 groups can be created.
3.3.4 Scenes
A scenario (e.g. "roller shutters up, lights off, heating off" when leaving the
flat) can be stored ("learned") in a scene and be called at a later time.
One or more channels are allocated to the scene for this purpose and set
as desired. After the scene has been stored, this scenario can be recalled at
any time by selecting the scene.