EasyManua.ls Logo

WAREMA climatronic - Procedure

WAREMA climatronic
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
890370_0•en•01.06.2009
We reserve the right to carry out improvements
20
WAREMA climatronic
®
Installation Instructions
4.2 Procedure
Follow the points below in the order given:
First determine where the individual components are to be installed. Refer to
the specifications in this chapter and in the sensor and switch actuator data
sheets.
NOTE The last page of the switch actuator instructions contains tables for noting
down the terminal assignments. This is absolutely essential for the future
software-specific allocation on the control panel of the WAREMA climatronic.
Also affix an ID sticker of the actuator on the field provided for this purpose
and note down the installation location and any additional information on the
device, if necessary.
Do not use lines of a larger cross-section than specified.
Then determine which cables are required to connect the components with
one another. To do this, please refer to the "Wiring diagrams" chapter. Be
aware that terminal sets of multi-pole products must be connected to the
same terminal block of a switch actuator and not to two separate ones. Lay
the required lines.
Preferably use cable ducts to route the motor lines.
WARNING
Electrical equipment must be installed in an easily accessible location
(VDE0100).
Install and wire the individual components.
CAUTION
When wiring bus terminals that have already been plugged in, only needle-
nosed pliers may be used to pull them off again to prevent damage to the
bus terminals or the contact pins.
Check the wiring before switching on the power supply to the control.
Then commission the unit. Only then will the control be ready to use. The
steps required for commissioning are explained in detail in these instructions.
Check the correct running direction of the sun shading product by operating
the "Up" and "Down" buttons on the control.
Check that the connected sensors are functioning properly.
Check whether the sun shading products are moved to a safe position when
a wind alarm is triggered.
Activate the precipitation control and check whether the control function re-
sponds to precipitation (moisten the sensor surface with water).
Then adjust the functioning of the system to the ambient conditions and spe-
cial requirements.
Installation