B.3 Parameter Table
412 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
20 Drive Overheat Pre-alarm (oH)
Closed: Heatsink temperature exceeds the parameter L8-02 value.
215
2F Maintenance Period
Closed: Cooling fan, electrolytic capacitors, IGBTs, or the soft charge bypass relay may require maintenance.
215
30 During Torque Limit
Closed: When the torque limit has been reached.
215
33 Within Position Lock Bandwidth
Closed: Position deviation is within the Position Lock Bandwidth.
215
37 During Frequency Output
Open: No frequency output from drive when stopped with baseblock, stopped with DC injection braking during initial
excitation, or stopped with short circuit braking.
Closed: Drive is outputting a frequency.
215
47 Input Phase Loss
Closed: Input phase loss has occurred
Open: Normal operation (no phase loss detected)
216
4E Braking Transistor Fault (rr)
Closed: The built-in dynamic braking transistor failed.
Note: This function is not available in models CIMR-LU20145 to 20415, 40075 to 40216, or 50052 to
50200.
216
50 Brake Control
Close: Release brake
Open: Apply brake
216
51 Output Contactor Control
Closed: Close output contactor
216
52 Door Zone Reached
Closed: Indicates that the door zone has been reached.
216
53 Not Zero Speed
Closed: Speed is greater than the zero speed level set to S1-01
Open: Operating at zero speed level
216
54 Light Load Direction
Closed: Light load direction is up
Open: Light load direction is down
216
55
Light Load Direction Detection
Status
Closed: Ready for Light Load Direction Search
Open: Light Load Detection in progress
216
58 Safe Disable Status
Closed: Safe Disable terminals H1-HC and H2-HC are open, drive is in a baseblock state
Open: Safe Disable terminals H1-HC and H2-HC are closed (normal operation)
216
5C
<44>
Motor Current Monitor
Open: Output current is greater than the value of L8-99.
Closed: Output current is less than or equal to the value of L8-99.
216
60 Internal Cooling Fan Alarm
Closed: Internal cooling fan alarm
216
61 Motor Pole Search Status
Closed: Motor pole search successful
216
100 to 161 Function 0 to 61 with Inverse Output
Inverts the output switching of the multi-function output functions.
Sets the last two digits of 1 to reverse the output signal of that specific function.
217
<44> Available in drive software versions PRG: 7017 or later.
H2 Multi-Function Digital Output Settings
H2-
Setting
Function Description Page