H2: Multi-Function Digital Outputs
56 Motor Contactor Feedback
Open: Motor contactor open
Closed: Motor contactor closed (N.O.)
207
57 High Speed Limit (Up)
Closed: Uses the leveling speed as the maximum speed when going up.
207
58 High Speed Limit (Down)
Closed: Uses the leveling speed as the maximum speed when going down.
207
5A
<44>
Motor Contactor Feedback 2
Open: Motor contactor closed (N.C.)
Closed: Motor contactor open
207
5B
<44>
Brake Feedback 2
Open: Brake open (N.C.)
Closed: Brake closed
207
5C Floor Sensor
Closed: Initiate Direct Landing (S5-10 = 1)
207
67 Communications Test Mode
Tests the MEMOBUS/Modbus RS-485/422 interface. Displays “PASS” if the test completes successfully.
207
79 Brake Feedback
Open: Brake closed
Closed: Brake open (N.O.)
207
<44> Available in drive software versions PRG: 7017 or later.
No.(Addr.) Name Description Setting Page
H2-01
(40BH)
Terminals M1-M2 Function
Selection (relay)
Refer to H2 Multi-Function Digital Output Settings on page 410 for a description of setting
values.
Default: 50
Min: 0
Max: 161
208
H2-02
(40CH)
Terminals M3-M4 Function
Selection (relay)
Default: 51
Min: 0
Max: 161
208
H2-03
(40DH)
Terminals M5-M6 Function
Selection (relay)
Default: 6
Min: 0
Max: 161
208
H2-04
(40EH)
Terminal P1-C1 Function
Selection (photocoupler)
Default: 37
Min: 0
Max: 161
208
H2-05
(40FH)
Terminal P2-C2 Function
Selection (photocoupler)
Default: F
Min: 0
Max: 161
208
H2 Multi-Function Digital Output Settings
H2-
Setting
Function Description Page
0 During Run
Closed: An Up/Down command is active or voltage is output.
208
1 Zero Speed
Open: Output speed is greater than the value of E1-09 (Minimum Output Frequency) or S1-01 (Zero Speed Level at
Stop).
Closed: Output frequency is less than or equal to the value of E1-09 (Minimum Output Frequency) or S1-01 (Zero
Speed Level at Stop).
208
2 Speed Agree 1
Closed: Output speed equals the speed reference (plus or minus the hysteresis set to L4-02).
209
3 User-set Speed Agree 1
Closed: Output speed and speed reference equal L4-01 (plus or minus the hysteresis set to L4-02).
209
4 Speed Detection 1
Closed: Output speed is less than or equal to the value in L4-01 with hysteresis determined by L4-02.
210
H1 Multi-Function Digital Input Settings
H1-
Setting
Function Description Page
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
CLV
CLV/PM
V/f OLV
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
SIEP_C710616_38F_5_0.book 410 ージ 015年11月9日 月曜日 午後3時36分

Table of Contents

Other manuals for YASKAWA L1000A

Related product manuals