12.2 Alarm Displays
12.2.2 Troubleshooting Alarms
12
Maintenance
12-29
A.8A5:
External Encoder
Overspeed
An overspeed error
was detected in the
external encoder.
Check the maximum
speed of the external
encoder.
Keep the external
encoder below its maxi-
mum speed.
A.8A6:
External Encoder
Overheated
An overheating error
was detected in the
external encoder.
Replace the external
encoder.
A.b10:
Speed Reference
A/D Error
(Detected when
the servo is
turned ON.)
A malfunction
occurred in the speed
reference input sec-
tion.
Reset the alarm and
restart operation.
page 12-42
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.b11:
Speed Reference
A/D Data Error
A malfunction
occurred in the speed
reference input sec-
tion.
Reset the alarm and
restart operation.
page 12-42
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.b20:
Torque Refer-
ence A/D Error
(Detected when
the servo is
turned ON.)
A malfunction
occurred in the read-
ing section for the
torque reference
input.
Reset the alarm and
restart operation.
page 12-42
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.b33:
Current Detec-
tion Error 3
A failure occurred in
the current detection
circuit.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.bF0:
System Alarm 0
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.bF1:
System Alarm 1
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.bF2:
System Alarm 2
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Continued on next page.