EasyManua.ls Logo

YASKAWA SGD7S series - Page 529

YASKAWA SGD7S series
629 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.3 Warning Displays
12.3.2 Troubleshooting Warnings
12
Maintenance
12-53
A.93B:
Overheat Warning
The surrounding
temperature is too
high.
Check the surrounding
temperature using a
thermostat.
Lower the surrounding tem-
perature by improving the
installation conditions of the
Linear Servomotor or the
machine.
Operation was
performed under
an excessive load.
Use the accumulated
load ratio to check the
load during operation.
Reconsider the load and
operating conditions.
A failure occurred
in the SERVO-
PACK.
The SERVOPACK may be
faulty. Replace the SERVO-
PACK.
The temperature
detection circuit in
the Linear Servo-
motor is faulty or
the sensor
attached to the
machine is faulty.
The temperature detection
circuit in the Linear Servo-
motor may be faulty or the
sensor attached to the
machine may be faulty.
Replace the Linear Servo-
motor or repair the sensor
attached to the machine.
A.941:
Change of Parame-
ters Requires
Restart
Parameters have
been changed
that require the
power supply to
be turned OFF
and ON again.
Turn the power supply to
the SERVOPACK OFF and
ON again.
A.942:
Speed Ripple Com-
pensation Informa-
tion Disagreement
The speed ripple
compensation
information stored
in the encoder
does not agree
with the speed
ripple compensa-
tion information
stored in the
SERVOPACK.
Reset the speed ripple
compensation value on the
SigmaWin+.
page 8-60
Set Pn423 to n.1 (Do
not detect A.942 alarms).
However, changing the set-
ting may increase the speed
ripple.
page 8-60
Set Pn423 to n.0
(Disable speed ripple com-
pensation). However,
changing the setting may
increase the speed ripple.
page 8-60
A.971:
Undervoltage
For a 200-V
SERVOPACK, the
AC power supply
voltage dropped
below 140 V.
Measure the power
supply voltage.
Set the power supply volt-
age within the specified
range.
For a 100-V
SERVOPACK, the
AC power supply
voltage dropped
below 60 V.
Measure the power
supply voltage.
Set the power supply volt-
age within the specified
range.
The power supply
voltage dropped
during operation.
Measure the power
supply voltage.
Increase the power supply
capacity.
A momentary
power interrup-
tion occurred.
Measure the power
supply voltage.
If you have changed the
setting of Pn509 (Momen-
tary Power Interruption Hold
Time), decrease the setting.
page 6-13
The SERVOPACK
fuse is blown out.
Replace the SERVOPACK
and connect a reactor.
page 4-24
A failure occurred
in the SERVO-
PACK.
The SERVOPACK may be
faulty. Replace the SERVO-
PACK.
Continued on next page.
Continued from previous page.
Warning Number:
Warning Name
Possible Cause Confirmation Correction Reference

Table of Contents

Related product manuals