EasyManua.ls Logo

YASKAWA SGDV-OCA05A

YASKAWA SGDV-OCA05A
576 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14.2 Alarm Displays
14.2.2 Troubleshooting Alarms
14
Maintenance
14-39
A.E71:
Safety Option
Module Detec-
tion Failure
There is a faulty con-
nection between the
SERVOPACK and the
Safety Option Module.
Check the connection
between the SERVO-
PACK and the Safety
Option Module.
Correctly connect the
Safety Option Module.
The Safety Option
Module was discon-
nected.
Reset the Option Module
configuration error and
turn the power supply to
the SERVOPACK OFF and
ON again.
page 14-46
A failure occurred in
the Command Option
Module.
Replace the Safety Option
Module.
A failure occurred in
the SERVOPACK.
Replace the SERVO-
PACK.
A.E72:
Feedback Option
Module Detec-
tion Failure
There is a faulty con-
nection between the
SERVOPACK and the
Feedback Option
Module.
Check the connection
between the SERVO-
PACK and the Feed-
back Option Module.
Correctly connect the
Feedback Option Module.
The Feedback Option
Module was discon-
nected.
Reset the Option Module
configuration error and
turn the power supply to
the SERVOPACK OFF and
ON again.
page 14-46
A failure occurred in
the Feedback Option
Module.
Replace the Feedback
Option Module.
A failure occurred in
the SERVOPACK.
Replace the SERVO-
PACK.
A.E73:
Unsupported
Command Option
Module
A failure occurred in
the Command Option
Module.
Replace the Command
Option Module.
An unsupported Com-
mand Option Module
was connected.
Connect a supported
Command Option Mod-
ule.
A.E74:
Unsupported
Safety Option
Module
A failure occurred in
the Safety Option
Module.
Replace the Safety Option
Module.
An unsupported
Safety Option Module
was connected.
Connect a supported
Safety Option Module.
A.E75
*2
:
Unsupported
Feedback Option
Module
A failure occurred in
the Feedback Option
Module.
Replace the Feedback
Option Module.
An unsupported
Feedback Option
Module was con-
nected.
Refer to the catalog for
the connected Feed-
back Option Module or
the SERVOPACK man-
ual.
Connect a supported
Feedback Option Module.
A.E80:
Command Option
Module Detec-
tion Inconsistency
The Command Option
Module was replaced
with a different model.
Reset the Option Module
configuration error and
turn the power supply to
the SERVOPACK OFF and
ON again.
Continued on next page.
Continued from previous page.
Alarm Number:
Alarm Name
Possible Cause Confirmation Correction Reference

Table of Contents

Related product manuals