15.1 List of Parameters
15.1.2 List of Parameters
15-14
Pn164 2
Anti-Resonance Filter
Time Constant 1 Cor-
rection
-1,000 to
1,000
0.01 ms 0 All
Immedi-
ately
Tuning
page
8-51
Pn165 2
Anti-Resonance Filter
Time Constant 2 Cor-
rection
-1,000 to
1,000
0.01 ms 0 All
Immedi-
ately
Tuning
page
8-51
Pn166 2
Anti-Resonance Damp-
ing Gain 2
0 to 1,000 1% 0 All
Immedi-
ately
Tuning
page
8-54
Pn170
2
Tuning-less Function-
Related Selections
0000h to
2711h
1401h All
Setup
page
8-11
Pn181 2
Mode Switching Level
for Speed Reference
0 to 10,000 1 mm/s 0 Linear
Immedi-
ately
Tuning
page
8-90
Pn182 2
Mode Switching Level
for Acceleration
0 to 30,000
1 mm/
s
2
0Linear
Immedi-
ately
Tuning
page
8-90
Pn205 2 Multiturn Limit 0 to 65,535 1 rev 65535 Rotary
After
restart
Setup
page
6-19
Pn207
2
Position Control Func-
tion Selections
0000h to
2210h
0010h All
After
restart
Setup
Pn20A 4
Number of External
Encoder Scale Pitches
4 to
1,048,576
1 scale
pitch/
revolu-
tion
32768 Rotary
After
restart
Setup
page
10-7
Pn20E 4
Electronic Gear Ratio
(Numerator)
1 to
1,073,741,824
164 All
After
restart
Setup
page
5-41
Pn210 4
Electronic Gear Ratio
(Denominator)
1 to
1,073,741,824
11 All
After
restart
Setup
page
5-41
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Tuning-less Selection
When
Enabled
0 Disable tuning-less function.
After
restart
1 Enable tuning-less function.
n.X Reserved parameter (Do not change.)
n.X
Rigidity Level
When
Enabled
0 to 7 Set the rigidity level.
Immedi-
ately
n.X
Tuning-less Load Level
When
Enabled
0 to 2 Set the load level for the tuning-less function.
Immedi-
ately
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X
/COIN (Positioning Completion Output) Signal Output Timing
Refer-
ence
0
Output when the absolute value of the position deviation is the
same or less than the setting of Pn522 (Positioning Completed
Width).
page 8-661
Output when the absolute value of the position error is the same
or less than the setting of Pn522 (Positioning Completed Width)
and the reference after the position reference filter is 0.
2
Output when the absolute value of the position error is the same
or less than the setting of Pn522 (Positioning Completed Width)
and the reference input is 0.