15.2 Parameter Recording Table
15-32
Pn55A 1
Power Consumption Moni-
tor Unit Time
Immediately
Pn560 400
Residual Vibration Detec-
tion Width
Immediately
Pn561 100 Overshoot Detection Level Immediately
Pn581 20 Zero Speed Level Immediately
Pn582 10 Reserved parameter −
Pn583 10
Brake Reference Output
Speed Level
Immediately
Pn584 10000
Speed Limit Level at Servo
ON
Immediately
Pn585 50
Program Jogging Move-
ment Speed
Immediately
Pn586 0
Motor Running Cooling
Ratio
Immediately
Pn587 0000h Reserved parameter −
Pn600 0
Regenerative Resistor
Capacity
Immediately
Pn601 0
Dynamic Brake Resistor
Allowable Energy Con-
sumption
After restart
Pn603 0 Regenerative Resistance Immediately
Pn604 0 Dynamic Brake Resistance After restart
Pn61A
0000h
Overheat Protection Selec-
tions
After restart
Pn61B
250 Overheat Alarm Level Immediately
Pn61C
100 Overheat Warning Level Immediately
Pn61D
0 Overheat Alarm Filter Time Immediately
Pn621 to
Pn628
− Reserved parameter −
PnB01 0001h Origin Return Direction Immediately
PnB03 20000 Origin Approach Speed Immediately
PnB04 10000 Origin Return Creep Speed Immediately
PnB05 0
Final Travel Distance for
Origin Return
Immediately
PnB09 0 Origin Offset Immediately
PnB12 0000h Coordinate Type Selection Immediately
PnB13 360000
Reference Units per
Machine Revolution
After restart
PnB16
2147483
647
Forward Software Limit Immediately
PnB17
-214748
3647
Reverse Software Limit Immediately
PnB18 0000h
Software Limit Action
Selection
Immediately
PnB1A 0000h
Hardware Limit Action
Selection
Immediately
PnB1C 0000h
External Stop Action Selec-
tion
Immediately
PnB21 400000 Feed Speed Immediately
PnB26 0003h
Acceleration/Deceleration
Type
Immediately
PnB29 0000h Filter Selection Immediately
PnB2A 4000000 Acceleration Rate Immediately
Continued on next page.
Continued from previous page.
Parameter
No.
Default
Setting
Name
When
Enabled