5.11 S: Functions for Textile Applications
262 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
u S9: Synchronous Operation
n S9-03: Speed Detection Change Rate Limit
Assigns a limit to how much the motor speed detection may fluctuate each millisecond.
n
S9-06: Speed Detection Width After Coasting
Sets the motor speed detection width as soon as the motor is done coasting.
Once the motor is done coasting, the drive will apply the motor speed detection value if the value detected is less than
S9-06 plus the previous value.
u T: Motor Tuning
Auto-Tuning automatically sets and tunes parameters required for optimal motor performance.
Refer to Auto-Tuning on page 87 for details on Auto-Tuning parameters.
No. Name Setting Range Default
S9-03 Speed Detection Change Rate Limit 0.00 to 5.00 Hz 0.01 Hz
No. Name Setting Range Default
S9-06 Speed Detection Width After Coasting 0.00 to 1.00 Hz 0.20 Hz