354 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
A.3 Three-Phase 400 V Class Drives
A.3 Three-Phase 400 V Class Drives
Table A.3 Power Ratings (Three-Phase 400 V Class)
Item
<1> The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor rated current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring
conditions, and power supply impedance.
<3> DC is not available for UL/CE standards.
<4> Rated motor capacity is calculated with a rated output voltage of 440 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency can be increased up the 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.
<7> User-adjustable
<8> Carrier frequency can be increased up the 5 kHz while keeping this current rating. Higher carrier frequency settings require derating.
Specification
CIMR-T4A 0002 0004 0005 0007 0009 0011 0018 0023 0031 0038 0044 0058 0072 0088 0103 0139 0165 0208 0250 0296 0362
Maximum Applicable Motor
Capacity (kW)
<1>
HD Rating 0.55 1.1 1.5 2.2 3 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160
ND Rating 0.75 1.5 2.2 3 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 185
Input
Input Current
(A)
<2>
HD Rating 1.8 3.2 4.4 6 8.2 10.4 15 20 29 39 44 43 58 71 86 105 142 170 207 248 300
ND Rating 2.1 4.3 5.9 8.1 9.4 14 20 24 38 44 52 58 71 86 105 142 170 207 248 300 346
Rated Voltage
Rated Frequency
Three-phase 380 to 480 Vac 50/60 Hz/510 to 680 Vdc
<3>
Allowable Voltage Fluctuation –15 to 10%
Allowable Frequency Fluctuation ±5%
Input Power (kVA)
HD Rating 1.4 2.3 4.3 6.1 8.1 10.0 14.6 19.2 28.4 37.5 46.6 39.3 53.0 64.9 78.6 96.0 130 156 189 227 274
ND Rating 2.3 4.3 6.1 8.1 10.0 14.4 19.4 28.4 37.5 46.6 54.9 53.0 64.9 78.6 96.0 130 156 189 227 274 316
Output
Rated Output
Capacity (kVA)
<4>
HD Rating
1.4
<6>
2.6
<6>
3.7
<6>
4.2
<6>
5.5
<6>
7
<6>
11.3
<6>
13.7
<6>
18.3
<6>
24
<6>
30
<6>
34
<6>
46
<6>
57
<6>
69
<6>
85
<8>
114
<8>
137
<8>
165
<8>
198
<8>
232
<8>
ND Rating
<5>
1.6 3.1 4.1 5.3 6.7 8.5 13.3 17.5 24 29 34 44 55 67 78 106 126 159 191 226 276
Rated Output
Current (A)
HD Rating
1.8
<6>
3.4
<6>
4.8
<6>
5.5
<6>
7.2
<6>
9.2
<6>
14.8
<6>
18
<6>
24
<6>
31
<6>
39
<6>
45
<6>
60
<6>
75
<6>
91
<6>
112
<8>
150
<8>
180
<8>
216
<8>
260
<8>
304
<8>
ND Rating
<5>
2.1 4.1 5.4 6.9 8.8 11.1 17.5 23 31 38 44 58 72 88 103 139 165 208 250 296 362
Overload Tolerance
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
ND Rating: 120% of rated output current for 60 s
Carrier Frequency
1 to 15 kHz
<7> 1 and 10 kHz <7>
Maximum Output Voltage (V)
Three-phase 380 to 480 V (proportional to input voltage)
Maximum Output Frequency (Hz)
400 Hz
<7>