3.5 Terminal Cover
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual 51
Electrical Installation
3
u CIMR-T2A0110 to 0415, 4A0058 to 0362
n Removing the Terminal Cover
1. Loosen the four screws on the terminal cover, then pull down on the cover.
CAUTION! Do not completely remove the cover screws, just loosen them. If the cover screws are removed completely, the terminal
cover may fall off causing an injury. Take special care when removing/reattaching the terminal covers for larger drives.
Figure 3.10
Figure 3.6 Removing the Terminal Cover
2. Pull forward on the terminal cover to free it from the drive.
Figure 3.11
Figure 3.7 Removing the Terminal Cover
n Reattaching the Terminal Cover
Once wiring to the terminal board and other devices is complete, double check all connections and finally reattach the
terminal cover. Refer to Wiring the Main Circuit Terminal on page 59 and Wiring the Control Circuit Terminal on
page 62 for details on wiring.
Figure 3.12
Figure 3.8 Reattaching the Terminal Cover
YEG
YEG
Connect ground wiring first,
followed by the main circuit,
and then wire the control circuit.
Power lines and signal wiring
exit through the opening provided.
YEG