7.2 Inspection
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual 315
Periodic Inspection &
Maintenance
7
7.2 Inspection
Power electronics have limited life and may exhibit changes in characteristics or performance deterioration after years of
use under normal conditions. To help avoid such problems, it is important to perform preventive maintenance and
periodic inspection on the drive.
Drives contain a variety of power electronics such as power transistors, semiconductors, capacitors, resistors, fans, and
relays. The electronics in the drive serve a critical role in maintaining proper motor control.
Follow the inspection lists provided in this chapter as a part of a regular maintenance program.
Note: The drive will require more frequent inspection if it is placed in harsh environments, such as:
High ambient temperatures
Frequent starting and stopping
Fluctuations in the AC supply or load
Excessive vibrations or shock loading
Dust, metal dust, salt, sulfuric acid, chlorine atmospheres
Poor storage conditions.
Perform the first equipment inspection one to two years after installation.
u Recommended Daily Inspection
Table 7.1 outlines the recommended daily inspection for Yaskawa drives. Check the following items on a daily basis to
avoid premature deterioration in performance or product failure. Copy this checklist and mark the “Checked” column
after each inspection.
Table 7.1 General Recommended Daily Inspection Checklist
Inspection Category Inspection Points Corrective Action Checked
Motor Inspect for abnormal oscillation or noise coming from the motor.
Check the load coupling.
Measure motor vibration.
Tighten all loose components.
Cooling
Inspect for abnormal heat generated from the drive or motor and
visible discoloration.
Check for excessive load.
Loose connections
Check for dirty heatsink or motor.
Ambient temperature
Cooling Fan Inspect drive cooling fan and circulation fan operation.
Check for clogged or dirty fan.
Check fan operation drive parameter.
Environment
Verify the drive environment complies with the specifications
listed in Installation Environment on page 36.
Eliminate the source of contaminants or correct poor
environment.
Load
The drive output current should not be higher than the motor or
drive rating for an extended period of time.
Check for excessive load.
Check the motor parameter settings of the drive.
Power Supply Voltage Check main power supply and control voltages.
Correct the voltage or power supply to within nameplate
specifications.
Verify all main circuit phases.