B.3 Parameter Table
408 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
n o3: Copy Function
n o4: Maintenance Monitor Settings
u S: Functions for Textile Applications
The S parameters are designed specifically for textile applications. They set and adjust the Disturb function, gain levels
for the frequency reference, braking transistor characteristics, and various aspects of KEB.
n
S1: Disturb Function
No. (Addr.) Name Description Setting Page
o3-01
(515H)
Copy Function Selection
0: No action
1: Read parameters from the drive, saving them onto the digital operator.
2: Copy parameters from the digital operator, writing them to the drive.
3: Verify parameter settings on the drive to check if they match the data saved on the operator.
Default: 0
Min: 0
Max: 3
247
o3-02
(516H)
Copy Allowed Selection
0: Read operation prohibited
1: Read operation allowed
Default: 0
Min: 0
Max: 1
247
No. (Addr.) Name Description Setting Page
o4-01
(50BH)
Cumulative Operation Time
Setting
Sets the value for the cumulative operation time of the drive in units of 10 h.
Default: 0
Min: 0
Max: 9999
248
o4-02
(50CH)
Cumulative Operation Time
Selection
0: Logs power-on time
1: Logs operation time when the drive output is active (output operation time).
Default: 0
Min: 0
Max: 1
248
o4-03
(50EH)
Cooling Fan Operation Time
Setting
Sets the value of the fan operation time monitor U4-03 in units of 10 h.
Default: 0
Min: 0
Max: 9999
248
o4-05
(51DH)
Capacitor Maintenance Setting
Sets the value of the Maintenance Monitor for the capacitors. See U4-05 to check when the
capacitors may need to be replaced.
Default: 0%
Min: 0%
Max: 150%
248
o4-07
(523H)
DC Bus Pre-charge Relay
Maintenance Setting
Sets the value of the Maintenance Monitor for the soft charge bypass relay. See U4-06 to check
when the bypass relay may need to be replaced.
Default: 0%
Min: 0%
Max: 150%
248
o4-09
(525H)
IGBT Maintenance Setting
Sets the value of the Maintenance Monitor for the IGBTs. See U4-07 to check when the IGBTs
may need to be replaced.
Default: 0%
Min: 0%
Max: 150%
249
o4-11
(510H)
U2, U3 Initialize Selection
0: U2- and U3- monitor data is not reset when the drive is initialized (A1-03).
1: U2- and U3- monitor data is reset. After that, o4-11 will be reset to 0.
Default: 0
Min: 0
Max: 1
249
o4-12
(512H)
kWh Monitor Initialization
0: U4-10 and U4-11 monitor data is not reset when the drive is initialized (A1-03).
1: U4-10 and U4-11 monitor data is reset.
Default: 0
Min: 0
Max: 1
249
o4-13
(528H)
Number of Run Commands
Counter Initialization 0: Number of Run commands counter is not reset when the drive is initialized (A1-03).
1: Number of Run commands counter is reset.
Default: 0
Min: 0
Max: 1
249
No. (Addr.) Name Description Setting Page
S1-01
(680H)
Disturb Function Selection
0: Disabled
1: Enabled
2: Enabled, outputs the Disturb waveform during accel/decel
Default: 0
Min: 0
Max: 2
251
S1-02
(681H)
Disturb Function Amplitude
Set the amplitude of the Disturb waveform as a percentage of the frequency reference.
Default: 0.0%
Min: 0.0%
Max: 20.0%
251
S1-03
(682H)
Disturb Step
Sets the step applied at the end of disturb acceleration or deceleration as a percentage of the
Disturb amplitude in S1-02.
Default: 0.0%
Min: 0.0%
Max: 50.0%
251
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV