B.3 Parameter Table
416 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
U1-12
(4BH)
Drive Status
Verifies the drive operation status.
No signal output
available
––
U1-13
(4EH)
Terminal A1 Input Level
Displays the signal level to analog input terminal A1.
10 V: 100% 0.1%
U1-14
(4FH)
Terminal A2 Input Level
Displays the signal level to analog input terminal A2.
10 V: 100% 0.1%
U1-15
(50H)
Terminal A3 Input Level
Displays the signal level to analog input terminal A3.
10 V: 100% 0.1%
U1-16
(53H)
Output Frequency after Soft
Starter
Displays output frequency with ramp time and S-curves. Units determined by o1-03.
10 V: Max frequency 0.01 Hz
U1-17
(58H)
DI-A3 Input Status
Displays the reference value input from the DI-A3 option card.
Display will appear in hexadecimal as determined by the digital card input selection in F3-01.
3FFFF: Set (1 bit) + sign (1 bit) + 16 bit
No signal output
available
––
U1-18
(61H)
oPE Fault Parameter
Displays the parameter number that caused the oPE02 or oPE08 error.
No signal output
available
––
U1-19
(66H)
MEMOBUS/Modbus Error
Code
Displays the contents of a MEMOBUS/Modbus error.
No signal output
available
––
U1-21
(77H)
AI-A3 Terminal V1 Input
Voltage Monitor
Displays the input voltage to terminal V1 on analog input card AI-A3.
10 V: 100% 0.1%
U1-22
(72AH)
AI-A3 Terminal V2 Input
Voltage Monitor
Displays the input voltage to terminal V2 on analog input card AI-A3.
10 V: 100% 0.1%
U1-23
(72BH)
AI-A3 Terminal V3 Input
Voltage Monitor
Displays the input voltage to terminal V3 on analog input card AI-A3.
10 V: 100% 0.1%
U1-24
(7DH)
Input Pulse Monitor
Displays the frequency to pulse train input terminal RP.
Determined by H6-02 1 Hz
U1-25
(4DH)
Software Number (Flash)
FLASH ID
No signal output
available
––
U1-26
(5BH)
Software No. (ROM)
ROM ID
No signal output
available
––
<15> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<18> This value's number of decimal places depends on the drive model and the Heavy/Normal duty selection in parameter C6-01. The value will
have two decimal places (0.01 A) if the drive is set for a Maximum Applicable Motor Capacity up to 11 kW (refer to Table A.2 and Table A.3)
and one decimal place (0.1 A) if the set Maximum Applicable Motor Capacity is higher than 11 kW.
<36> This value's number of decimal places depends on the drive model and the Heavy/Normal duty selection in parameter C6-01. The value will
have two decimal places (0.01 kW) if the drive is set for a Maximum Applicable Motor Capacity up to 11 kW (refer to Table A.2 and
Table A.3) and one decimal place (0.1 kW) if the set Maximum Applicable Motor Capacity is higher than 11 kW.
<41> When using V/f Control, 10 V is the drive capacity in kW. When using one of the vector control modes, 10 V is the motor capacity (E2-11).
No. (Addr.) Name Description
Analog Output
Level
Unit Page
All Modes
During run
During zero-speed
During REV
During fault reset
signal input
During speed agree
Drive ready
During alarm
detection
During fault detection
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
CRC Error
Data Length Error
Not Used
Parity Error
Overrun Error
Framing Error
Timed Out
Not Used
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes