B.5 Parameter Defaults Determined by Drive Model (o2-04) and Duty Rating (C6-01)
430 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
No. Name Unit Default Settings
Model CIMR-T 4A0208 4A0250 4A0296 4A0362
C6-01 Drive Duty Selection
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04 Drive Model Selection Hex. A6 A7 A8 A9
E2-11 (E4-11) Motor rated Output kW 90 110 110 132 132 160 160 185
b3-04 V/f Gain during Speed Search % 60 60 60 60 60 60 60 60
b3-06 Output Current 1 during Speed Search 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
b8-03 Energy Saving Control Filter Time Constant s 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00
b8-04 Energy Saving Coefficient Value 38.91 36.23 36.23 32.79 32.79 30.13 30.13 30.57
C5-17 (C5-37) Motor Inertia
kgm
2
1.10 1.90 1.90 2.10 2.10 3.30 3.30 3.60
C6-02 Carrier Frequency Selection 1 1 1 1 1 1 1 1
E2-01 (E4-01) Motor Rated Current A 156 190 190 223 223 270 270 310
E2-02 (E4-02) Motor Rated Slip Hz 1.4 1.4 1.4 1.38 1.38 1.35 1.35 1.3
E2-03 (E4-03) Motor No-Load Current A 40 49 49 58 58 70 70 81
E2-05 (E4-05) Motor Line to Line Resistance Ω 0.056 0.046 0.046 0.035 0.035 0.029 0.029 0.025
E2-06 (E4-06) Motor Leakage Inductance % 20 20 20 20 20 20 20 20
E2-10 (E4-10) Motor Iron Loss for Torque Compensation W 1760 2150 2150 2350 2350 2850 2850 3200
E5-01 Motor Code Selection Hex. 1247 1247 1248 1248 1249 1249 124A 124A
L2-02 Momentary Power Loss Ride-Thru Time s 2 2 2 2 2 2 2 2
L2-03 Momentary Power Loss Minimum Baseblock Time s 1.5 1.7 1.7 1.7 1.7 1.8 1.8 1.9
L2-04 Momentary Power Loss Voltage Recovery Time s 1 1 1 1 1 1 1 1
L8-02 Overheat Alarm Level °C 120 120 120 120 125 125 130 130
L8-35 Installation Method Selection 0 0 0 0 0 0 0 0
L8-38 Carrier Frequency Reduction Selection 2 2 2 2 2 2 2 2
n1-03 Hunting Prevention Time Constant ms 30 30 30 30 30 30 30 30
n5-02 Motor Acceleration Time s 0.592 0.646 0.646 0.673 0.673 0.777 0.777 0.864
n9-12 On-Delay Compensation Time μs22222222
S6-01 DC Bus Capacity μF 7400 7400 6400 6400 7750 7750 11000 11000
S6-02 Motor Acceleration Time s 0.592 0.646 0.646 0.673 0.673 0.777 0.777 0.864

Table of Contents