B.6 Parameter Defaults Determined by Motor Code (E5-01)
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual 443
Parameter List
B
Table B.20 400 V, 1150 r/min Type Yaskawa SST4 Series Motor
No.
<1> Default setting value varies by the drive model (o2-04).
Name Unit Default Settings
E5-01
Motor Code Selection − 2432 2433 2435 2436 2438 243A 243B 243D 243E 243F 2440
Voltage Class V 400 400 400 400 400 400 400 400 400 400 400
Rated Power kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18 22
Rated Speed r/min 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150
E5-02 Motor Rated Power kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11.0 15 18.50 22.00
E5-03 Motor Rated Current A 0.89 1.72 3.02 4.58 7.40 10.21 13.75 19.5 27.7 32.7 39.2
E5-04 Number of Motor Poles − 66666666666
E5-05 Motor Stator Resistance Ω 10.720 6.080 4.336 2.143 1.428 1.199 0.648 0.460 0.325 0.260 0.209
E5-06 Motor d-Axis Inductance mH 122.20 61.16 70.24 46.20 33.87 41.67 21.24 17.76 12.83 11.68 10.09
E5-07 Motor q-Axis Inductance mH 170.80 97.12 90.04 60.28 42.98 69.15 33.04 22.72 17.19 15.16 16.25
E5-09 Motor Induction Voltage Constant 1
mVs/
rad
626.1 626.1 703.1 727.6 699.0 861.5 759.7 740.4 716.6 809.1 786.2
E5-24 Motor Induction Voltage Constant 2
mV/
(r/min)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04 Maximum Output Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5
E1-05 Maximum Voltage V 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5
E1-09 Minimum Output Frequency Hz 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9
C5-17 Motor Inertia
kgm
2
0.0022 0.0042 0.0081 0.0133 0.0168 0.027 0.044 0.054 0.063 0.113 0.137
n5-02 Motor Acceleration Time s 0.080 0.081 0.078 0.088 0.066 0.070 0.085 0.071 0.061 0.091 0.090
n8-49 d-Axis Current for High Efficiency Control % -8.4 -11.0 -9.9 -9.0 -11.4 -23.2 -22.1 -16.7 -20.2 -15.2 -27.7
S6-02
<1>
Motor Acceleration Time s 0.080 0.081 0.078 0.088 0.066 0.070 0.085 0.071 0.061 0.091 0.090
No.
<1> Default setting value varies by the drive model (o2-04).
Name Unit Default Settings
E5-01
Motor Code Selection − 2442 2443 2444 2445 2446 2447 2448 2449 244A 244C
Voltage Class V 400 400 400 400 400 400 400 400 400 400
Rated Power kW 30 37 45 55 75 90k 110 132 160 200
Rated Speed r/min 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150
E5-02 Motor Rated Power kW 30.00 37.00 45.00 55.00 75.00 90.00 110.00 132.00 160.00 200.00
E5-03 Motor Rated Current A 51.8 63.0 76.6 93.1 128.1 153.1 186.5 221.9 269.8 336.5
E5-04 Number of Motor Poles − 6666666666
E5-05 Motor Stator Resistance Ω 0.140 0.106 0.076 0.051 0.032 0.026 0.015 0.012 0.009 0.007
E5-06 Motor d-Axis Inductance mH 8.12 6.43 4.96 3.99 2.97 2.44 1.87 1.49 1.41 1.22
E5-07 Motor q-Axis Inductance mH 9.84 7.71 6.56 5.39 3.90 3.23 2.46 2.08 1.88 1.51
E5-09 Motor Induction Voltage Constant 1
mVs/
rad
888.8 857.7 941.6 853.8 829.6 835.6 833.4 848.6 889.1 915.0
E5-24 Motor Induction Voltage Constant 2
mV/
(r/min)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04 Maximum Output Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5
E1-05 Maximum Voltage V 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5
E1-09 Minimum Output Frequency Hz 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9
C5-17 Motor Inertia
kgm
2
0.252 0.304 0.410 0.55 0.82 0.96 1.60 1.95 2.82 3.70
n5-02 Motor Acceleration Time s 0.122 0.119 0.132 0.145 0.159 0.155 0.211 0.214 0.256 0.268
n8-49 d-Axis Current for High Efficiency Control % -9.8 -10.2 -11.5 -15.9 -15.7 -15.7 -14.7 -16.5 -14.1 -10.3
S6-02
<1>
Motor Acceleration Time s 0.122 0.119 0.132 0.145 0.159 0.155 0.211 0.214 0.256 0.268