Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
7
Bit 6 of 6.16 Drive status word 1 (page 156).
Running
8
Bit 2 of 6.11 Main status word (page 156).
Ready ref
9
Bit 8 of 6.11 Main status word (page 156).
At setpoint
10
Bit 2 of 6.19 Speed control status word (page 158).
Reverse
11
Bit 0 of 6.19 Speed control status word (page 158).
Zero speed
12
Bit 10 of 6.17 Drive status word 2 (page 156).
Above limit
13
Bit 7 of 6.11 Main status word (page 156).
Warning
14
Bit 3 of 6.11 Main status word (page 156).
Fault
15
Inverted bit 3 of 6.11 Main status word (page 156).
Fault (-1)
16
Bit 13 of 6.16 Drive status word 1 (page 156).
Start request
22
Bit 0 of 44.1 Brake control status (page 395).
Open brake command
23
Bit 11 of 6.16 Drive status word 1 (page 156).
Ext2 active
24
Bit 9 of 6.11 Main status word (page 156).
Remote control
33
Bit 0 of 32.1 Supervision status (page 341).
Supervision 1
34
Bit 1 of 32.1 Supervision status (page 341).
Supervision 2
35
Bit 2 of 32.1 Supervision status (page 341).
Supervision 3
40
Bit 0 of 10.99 RO/DIO control word (page 181).
RO/DIO control word
bit0
41
Bit 1 of 10.99 RO/DIO control word (page 181).
RO/DIO control word
bit1
42
Bit 2 of 10.99 RO/DIO control word (page 181).
RO/DIO control word
bit2
43
Bit 8 of 10.99 RO/DIO control word (page 181).
RO/DIO control word
bit8
44
Bit 9 of 10.99 RO/DIO control word (page 181).
RO/DIO control word
bit9
See Terms and abbreviations (page 132).
Other [bit]
Not energized / uint32
(Visible when 14.1 Module 1 type = FIO-01)
Selects a drive signal to be connected to digital input/output
DIO1 of the extension module when parameter 14.9 DIO1
function is set to Output.
DIO1 output source14.11
0Output is not energized.Not energized
1Output is energized.Energized
2
Bit 1 of 6.11 Main status word (page 156).
Ready run
4
Bit 0 of 6.16 Drive status word 1 (page 156).
Enabled
5
Bit 5 of 6.16 Drive status word 1 (page 156).
Started
6
Bit 1 of 6.17 Drive status word 2 (page 156).
Magnetized
7
Bit 6 of 6.16 Drive status word 1 (page 156).
Running
8
Bit 2 of 6.11 Main status word (page 156).
Ready ref
9
Bit 8 of 6.11 Main status word (page 156).
At setpoint
202 Parameters