Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
3
Drive generates an A7EE Control panel loss warning and
sets the speed to the speed defined by parameter 22.41
Speed ref safe (or 28.41 Frequency ref safe when
frequency reference is being used). This only occurs if
control is expected from the control panel, or if supervision
is forced using parameter 49.7 Panel comm supervision
force.
WARNING!
Make sure that it is safe to continue operation in
case of a communication break.
Speed ref safe
5
Drive generates an A7EE Control panel loss warning. This
only occurs if control is expected from the control panel,
or if supervision is forced using parameter 49.7 Panel
comm supervision force.
WARNING!
Make sure that it is safe to continue operation in
case of a communication break.
Warning
Done / uint16
Applies the settings of parameters 49.1 Node ID
number…49.5.
Note: Refreshing may cause a communication break, so
reconnecting the drive may be required.
Refresh settings49.6
0Refresh done or not requested.Done
1
Refresh parameters 49.1 Node ID number…49.5. The
value reverts automatically to Done.
Refresh
- / uint16Activates control panel communication monitoring
separately for each control location (see section Local
control vs. external control (page 23)).
The parameter is primarily intended for monitoring the
communication with the panel when it is connected to the
application program and not selected as a control source
by drive parameters.
Panel comm
supervision force
49.7
1 = Communication monitoring active when Ext 1 is being
used.
Ext 1b0
1 = Communication monitoring active when Ext 2 is being
used.
Ext 2b1
1 = Communication monitoring active when local control
is being used.
Localb2
Reservedb3…15
1 = 10000h…FFFFh
412 Parameters