276 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
18 Save/Recall (Setups, Screens, Data)
8-bit Bitmap image (*.bmp) — The complete screen image in a reduced
color (8- bit) bitmap format. See "To save BMP or PNG image files" on
page 277.
24-bit Bitmap image (*.bmp) — The complete screen image in a 24- bit
color bitmap format. See "To save BMP or PNG image files" on
page 277.
24-bit image (*.png) — The complete screen image in a 24-bit color PNG
format that uses lossless compression. Files are much smaller than
the BMP format. See "To save BMP or PNG image files" on page 277.
CSV data (*.csv) — This creates a file of comma- separated values of all
displayed channels and math waveforms. This format is suitable for
spreadsheet analysis. See "To save CSV, ASCII XY, or BIN data
files" on page 278.
ASCII XY data (*.csv) — This creates separate files of comma- separated
values for each displayed channel. This format is also suitable for
spreadsheets. See "To save CSV, ASCII XY, or BIN data files" on
page 278.
Reference Waveform data (*.h5) — Saves waveform data in a format that
can be recalled to one of the oscilloscope's reference waveform
locations. See "To save reference waveform files to a USB storage
device" on page 281.
Multi Channel Waveform data (*.h5) — Saves multiple channels of
waveform data in a format that can be opened by the N8900A
InfiniiView oscilloscope analysis software. You can recall the first
Analog or Math channel from a multi channel waveform data file.
Binary data (*.bin) — This creates a binary file, with a header, and data
in the form of time and voltage pairs. This file is much smaller than
the ASCII XY data file. See "To save CSV, ASCII XY, or BIN data
files" on page 278.
Lister data (*.csv) — This is a CSV format file containing serial decode
row information with commas separating the columns. See "To save
Lister data files" on page 280.
Mask (*.msk) — This creates a mask file in an Agilent proprietary
format that can be read by Agilent InfiniiVision oscilloscopes. A mask
data file includes some oscilloscope setup information, but not all
setup information. To save all setup information including the mask
data file, choose "Setup (*.scp)" format instead. See "To save
masks" on page 281.

Table of Contents

Other manuals for Agilent Technologies InfiniiVision 3000 X-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 3000 X-Series and is the answer not in the manual?

Agilent Technologies InfiniiVision 3000 X-Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 3000 X-Series
CategoryTest Equipment
LanguageEnglish

Related product manuals