Utility Settings 20
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide 297
To establish a LAN connection
Automatic
Configuration
1 Press [Utility] > I/O.
2 Press the LAN Settings softkey.
3 Press the Config softkey; then, turn the Entry knob to select Automatic,
and press the softkey again to enable it.
If your network supports DHCP or AutoIP, enabling Automatic lets the
oscilloscope use those services to get its LAN configuration settings
4 If your network provides Dynamic DNS, you can enable the Dynamic DNS
option to let the oscilloscope register its hostname and use the DNS
server for name resolution.
5 You can enable the Multicast DNS option to let the oscilloscope use
Multicast DNS for name resolution on small networks without a
conventional DNS server.
6 Connect the oscilloscope to the local area network (LAN) by inserting
the LAN cable into the "LAN" port on the rear panel of the
oscilloscope.
In a few moments the oscilloscope will connect to the network
automatically.
If the oscilloscope does not automatically connect to the network, press
[Utility] > I/O > LAN Reset. In a few moments the oscilloscope will connect
to the network.
Manual
Configuration
1 Get the oscilloscope's network parameters (host name, IP address,
subnet mask, gateway IP, DNS IP, etc.) from your network
administrator.
2 Press [Utility] > I/O.
NOTE
When you connect the oscilloscope to a LAN it is a good practice to limit access to the
oscilloscope by setting a password. By default, the oscilloscope is not password protected.
See "Setting a Password" on page 327 to set a password.
NOTE
Any time you modify the oscilloscope's hostname, it breaks the connection between the
oscilloscope and the LAN. You need to re-establish communication to the oscilloscope
using the new hostname.

Table of Contents

Other manuals for Agilent Technologies InfiniiVision 3000 X-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 3000 X-Series and is the answer not in the manual?

Agilent Technologies InfiniiVision 3000 X-Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 3000 X-Series
CategoryTest Equipment
LanguageEnglish

Related product manuals