36.
Manual Diagnostics (On/Off)
"dAEn"
This option allows the owner to enable
or
disable the
manual diagnostics option. Refer to
Testing Machine
and Electronic Control Functions
section for
more
information.
How to Program the Manual Diagnostics
(On/Off)
1.
Control must
be
in
Manual Mode. Refer to
Entering the Manual Mode.
2. Press the DELICATESIBULKY
(A)
or
the
COLD
(v)
keypad until
"Prog"
appears
in
the
display. Press the START (enter) keypad and
"AtS1" will appear
in
the display.
3. Press the DELICATESIBULKY
(A)
or
the
COLD
(v)
keypad to scroll through the
programmable options until
"dAEn"
appears
in
the display.
4.
When
"dAEn"
appears
in
the
display, press the
START (enter) keypad.
The
current Manual
Diagnostics status will appear
in
the display.
"on"
=Option Enabled
(factory default setting)
"oFF"
= Option Disabled
5. Press the DELICATESIBULKY
(A)
or
the
COLD
(v)
keypad to change the current status.
6. Press the START (enter) keypad when the
desired status appears in the display.
The
next
option,
"PtEn",
will appear in the display.
NOTE:
To
program
"PtEn"
(Production
Test Cycle
[OnJOff),
refer
to
option 37. To
program
other
options,
refer
to
the
appropriate
section.
How to Exit Programming Feature
Press the WARM «) keypad until the control returns
to Ready Mode.
Programming Control
37. Production Test Cycle (On/Off)
"PtEn"
This option allows the owner to enable
or
disable
access to the production test cycle. Refer to
Production Test Cycle section for
more
information.
How to Program the Production Test
Cycle (On/Off)
1.
Control must
be
in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the DELICATESIBULKY
(A)
or
the
COLD
(v)
keypad until
"Prog"
appears in the
display. Press the START (enter) keypad and
"AtS 1" will appear
in
the display.
3. Press the DELICATESIBULKY (A)
or
the
COLD
(v)
keypad to scroll through
the
programmable options until
"PtEn"
appears
in
the display.
4.
When
"PtEn"
appears
in
the
display, press the
START (enter) keypad.
The
current Production
Test Cycle status will appear
in
the display.
"on"
= Option Enabled
(factory default setting)
"oFF"
=Option Disabled
5. Press the DELICATESIBULKY
(A)
or
the
COLD
(v)
keypad to change
the
current status.
6. Press
the
START (enter) keypad
when
the
desired status appears in the display.
The
ftrst
option,
"AtS 1", will appear
in
the display.
NOTE:
To
program
"AtS1" (Vend
Price
#1),
refer
to
option 1. To
program
other
options,
refer
to
the
appropriate
section.
How
to
Exit Programming Feature
Press the WARM «) keypad until the control returns
to Ready Mode.
802952
@ Published
by
permission of the copyright owner -
DO
NOT
COPY
or
TRANSMIT
83