Version 6.8 539 Mediant 2600 E-SBC
User's Manual 43. Configuration Parameters Reference
Parameter Description
[SNMPTrapEnterpriseOid]
Defines the Trap Enterprise OID.
The default is eSNMP_AC_ENTERPRISE_OID.
The inner shift of the trap in the AcTrap subtree is added to
the end of the OID in this parameter.
Note: For this parameter to take effect, a device reset is
required.
[acUserInputAlarmDescription]
Defines the description of the input alarm.
[acUserInputAlarmSeverity]
Defines the severity of the input alarm.
[AlarmHistoryTableMaxSize]
Defines the maximum number of rows in the Alarm History
table. This parameter can be controlled by the Config Global
Entry Limit MIB (located in the Notification Log MIB).
The valid range is 50 to 1000. The default is 500.
Note: For this parameter to take effect, a device reset is
required.
[ActiveAlarmTableMaxSize] Defines the maximum number of currently active alarms that
can be displayed in the Active Alarms table. When the table
reaches this user-defined maximum capacity (i.e., full), the
device sends the SNMP trap event,
acActiveAlarmTableOverflow. If the table is full and a new
alarm is raised by the device
, the new alarm is not displayed in
the table.
The valid range is 100 to 600. The default is 200.
For more information on the Active Alarms table, see Viewing
Active Alarms on page 479.
Note:
For the parameter to take effect, a device reset is required.
To clear the acActiveAlarmTableOverflow trap, you must
reset the device. The reset also deletes all the alarms in
the Active Alarms table.
CLI: engine-id
[SNMPEngineIDString]
Defines the SNMP engine ID for SNMPv2/SNMPv3 agents.
This is used for authenticating a user attempting to access the
SNMP agent on the device.
The ID can be a string of up to 36 characters. The default is
00:00:00:00:00:00:00:00:00:00:00:00 (12 Hex octets
characters). The provided key must be set with 12 Hex values
delimited by a colon (":") in the format xx:xx:...:xx. For
example, 00:11:22:33:44:55:66:77:88:99:aa:bb
Notes:
For this parameter to take effect, a device reset is required.
Before setting this parameter, all SNMPv3 users must be
deleted; otherwise, the parameter setting is ignored.
If the supplied key does not pass validation of the 12 Hex
values input or it is set with the default value, the engine ID
is generated according to RFC 3411.
Web: SNMP Trap Destination Parameters
EMS: Network > SNMP Managers Table
CLI: configure system/snmp trap destination
Note: Up to five SNMP trap managers can be defined.