SIP User's Manual 370 Document #: LTRT-12801
MP-500 MSBG
Parameter Description
to the waiting call. The device that initiates the waiting call
plays a Call Waiting Ringback tone to the calling party
after a 182 response is received.
 Port = Port number.
 Module = Module number.
For example:
CallWaitingPerPort 0 = 0,1,1; (call waiting disabled for Port 1 of
Module 1)
CallWaitingPerPort 1 = 1,1,2; (call waiting enabled for Port 2 of
Module 1)
Notes:
 This parameter is applicable only to FXS ports.
 If this parameter is not configured (default), call waiting is
determined according to the global parameter
EnableCallWaiting.
 The device's Call Progress Tones file must include a 'call
waiting Ringback' tone (caller side) and a 'call waiting' tone
(called side, FXS interfaces only).
 The EnableHold parameter must be enabled on both the
calling and the called sides.
 For configuring this table using the Web interface, refer to
Configuring Call Waiting on page 218.
 For a description on using ini file table parameters, refer to
Structure of ini File Table Parameters on page 273.
Web: Number of Call Waiting
Indications
EMS: Call Waiting Number of
Indications
[NumberOfWaitingIndications]
Number of Call Waiting indications that are played to the called
telephone that is connected to the device (FXS only) for Call
Waiting.
The valid range is 1 to 100 indications. The default value is 2.
Web: Time Between Call Waiting
Indications
EMS: Call Waiting Time Between
Indications
[TimeBetweenWaitingIndicatio
ns]
Time (in seconds) between consecutive call waiting indications
(FXS only) for call waiting.
The valid range is 1 to 100. The default value is 10.
Web/EMS: Time Before Waiting
Indications
[TimeBeforeWaitingIndication]
Defines the interval (in seconds) before a call waiting indication is
played to the port that is currently in a call (FXS only).
The valid range is 0 to 100. The default time is 0 seconds.
Web/EMS: Waiting Beep
Duration
[WaitingBeepDuration]
Duration (in msec) of call waiting indications that are played to
the port that is receiving the call (FXS only).
The valid range is 100 to 65535. The default value is 300.
EMS: First Call Waiting Tone ID
[FirstCallWaitingToneID]
Determines the index of the first Call Waiting Tone in the Call
Progress Tone (CPT) file. This feature enables the called party to
distinguish between four different call origins (e.g., external
versus internal calls). The device plays the tone received in the
'play tone CallWaitingTone#' parameter of an INFO message and
the value of this parameter - 1.
The valid range is -1 to 100. The default value is -1 (not used).
Note: It is assumed that all Call Waiting Tones are defined in
sequence in the CPT file.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes mediapack MP-500 and is the answer not in the manual?

AudioCodes mediapack MP-500 Specifications

General IconGeneral
BrandAudioCodes
Modelmediapack MP-500
CategoryGateway
LanguageEnglish

Related product manuals