120 S850 Operation & Maintenance Manual
HEATING, VENTILATION AND AIR CONDITIONING (HVAC) (CONT’D)
Evaporator / Heater Coil (Cont’d)
Later Models (Cont’d)
Figure 181
Clean the plenum drains (Item 1) [Figure 181] to ensure
they are not plugged by debris.
Inspect the cover seal (Item 2) [Figure 181] for breaks
and tears. Ensure the seal is firmly attached all around
t
he cover. See your Bobcat dealer for a replacement seal.
Figure 182
NOTE: The bosses (Item 1) fit inside the core
supports (Item 2) [Figure 182] when the cover
is installed. Deformity of the cover indicates
they are out of position.
NOTE: Improper cover installation can damage the
seal, which may lead to HVAC component
failure. Perform the following steps in the
order given to prevent cover seal damage.
Figure 183
1. Hold the cover in place and fasten two latches (Item
1) [Figure 183].
Figure 184
2. Push the cover up in three places (Items 1, 2, and 3)
until the slots snap into place on the tabs. This slot
(Inset) [Figure 184] is correctly fastened.
Dealer Copy -- Not for Resale