3.5.3 Description of outputs
On CEIA Integrated Systems, some of this outputs are already connected and configured.
OUTPUTS
Use or description with activated line
CONNECTION
Name on diagram
Auxiliary relay
Signal of a specific status of the Metal Detector (programmable).
J01
N/A
AUX RELAY
Test request relay
Request signal for Periodic Test, Test in Progress or Verified Test status
(programmable).
J01
N/A
TEST REQ RELAY
Upstream belt relay (only with Conveyor Control System or encoder)
Signal of moving belt (e.g. for consent to an upstream belt or other machine in the
line).
J01
N/A
PREC CONV
RELAY
Machine Ready relay
Signal that Metal Detector or Integrated System is operational.
J02 J1
READY RELAY
Ejection relay
Signal of ejection.
J02 J1
EJECT RELAY
Alarm relay
Signal of metal alarm.
J02
N/A
ALARM RELAY
Ejector in operation
Activation of the single or double solenoid ejector.
J14
N/A
EJECT NO
Ejector in operation
Deactivation of the double solenoid ejector.
J14
N/A
EJECT NC
Bin unlock
Activation of the rejected bin electric lock.
J15
N/A
BIN UNLOCK
Connection of optical/acoustic signalling devices.
J18
N/A
-
00211AL_ board Standard 00211ALM board Complete 00211ALM board
J14 J15
J01 J02
J18