Air conditioning control system
268
11.5 Cooling pipeline system
11.5.1 Overview
! Caution
The refrigerant must be completely evacuated before performing maintenance on
the air conditioning refrigeration system pipelines.
Use the special equipment to evacuate the refrigerant.
Wear goggles and gloves when evacuating refrigerant.
Maintain natural ventilation in the work area and turn on the exhaust device in the
workshop.
After opening air conditioning refrigeration system pipelines, it is necessary to seal
it immediately to prevent moisture and dirt from entering.
The pipeline sealing ring of the air conditioning refrigeration system is a disposable
component that is soaked with refrigerant oil before installation.
A kink or bend in the refrigeration pipeline system can reduce the flow of refrigerant,
resulting in a decrease in the cooling capacity of the air conditioning system.
11.5.2 Air conditioning compressor assembly
Tips for maintenance of air conditioning compressor
If it is necessary to replenish refrigerant oil to the compressor, the specified
refrigerant oil must be used and must not be mixed with other types of refrigerant oil.
Excessive refrigerant filling can cause bearing fault in the compressor.
Only fill the refrigerant from the high pressure side of the compressor, otherwise the
internal components of the compressor will be damaged.