Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
11. IVCurve:SEQuence
Description: Sets all the parameters for a Sequence in the IV-Program.
Syntax: IVCurve:SEQuence <arg1><,><arg2><,><arg3><,><arg4>
Parameter: Arg1: Sequence Number (NR1: 1-100)
Arg2: Sequence TYPE (NR1 0:Auto , 1:Manual )
Arg3: Sequence FILE (NR1: 1 - 100)
Arg4: Sequence TIME (NR1 Unit: SEC, only valid when Sequence
Type is set to AUTO.)
Example: Sets Sequence 5 to TYPE=AUTO,FILE NO=99, TIME=10 Sec
IVCurve:SEQuence 5,0,99,10
Query Syntax: IVCurve:SEQ?
Return Parameter: SEQ NO,TYPE,FILE NO,TIME
Query Example: IVC:SEQ?
Return Example: 5,0,99,10
Ensure the IV-Program has the desired sequence before selecting it. If not, use
PROG:ADD command to add a new Sequence.
12. IVCurve:SEQuence:RUN?
Description: Queries the running status of the IV-Program.
Query Syntax: IVCurve:SEQuence:RUN?
Return Parameter: <ARG1>,<ARG2>,... ,<ARG7>
<ARG1> Current running status.
0: STOP
1:RUNNING
<ARG2> Program No. currently running.
<ARG3> Remaining count of the Program currently running.
<ARG4> Sequence No. currenly running.
<ARG5> Sequence Type (0: AUTO, 1: MANUAL).
<ARG6> File No. currently running.
<ARG7> Current running time in second(s).
Query Example: IVC:SEQ:RUN?
Return Example: 1,2,3,0,5,1,123
(Return the status: RUNNING,
Program No=2,
Cnt_Remain=1,
Sequence No=3,
Sequence Type=AUTO,
File No=5,
Time=123 sec.)
13. IVCurve:CONFigure:CONTrol
Description: Sets the IV Curve output control mode.
Query Syntax: IVCurve:CONFigure:CONTrol?
Parameter: CC | CV
Example: VC:CONF:CONT CC
IVC:CONF:CONT CV
Query Example: IVC:CONF:CONT?
Return Example: CC or CV