EasyManuals Logo

Cisco A9K-SIP-700 Command Reference

Cisco A9K-SIP-700
590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #268 background imageLoading...
Page #268 background image
lpts punt excessive-flow-trap dampening
To enable false positive suppression through dampening, use the lpts punt excessive-flow-trap dampening
command in Global Configuration mode. To remove this configuration, use the no form of this command.
lpts punt excessive flow trap dampening [ time ]
no lpts punt excessive flow trap dampening [ time ]
Syntax Description
The time (in milliseconds) within which a second bad actor notification must arrive to
consider the flow as a repeated offender.
The range is from 1 to 60000; the default is 30000 milliseconds (30 seconds).
time
Command Default
By default, the dampening feature is disabled.
Command Modes
Global configuration
Command History
ModificationRelease
This command was introduced.Release 5.3.0
Usage Guidelines
No specific guidelines impact the use of this command.
Task ID
OperationTask ID
read, writeconfig-services
Examples
This example shows how to configure a dampening time of 40 milliseconds:
RP/0/RSP0/CPU0:router#configure
RP/0/RSP0/CPU0:router(config)#lpts punt excessive-flow-trap dampening 40
Cisco ASR 9000 Series Aggregation Services Router Broadband Network Gateway Command Reference,
Release 5.2.x
254
Excessive Punt Flow Trap Commands
lpts punt excessive-flow-trap dampening

Table of Contents

Other manuals for Cisco A9K-SIP-700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco A9K-SIP-700 and is the answer not in the manual?

Cisco A9K-SIP-700 Specifications

General IconGeneral
BrandCisco
ModelA9K-SIP-700
CategoryNetwork Router
LanguageEnglish

Related product manuals