EasyManuals Logo

Cisco Catalyst 3560-X User Manual

Cisco Catalyst 3560-X
1538 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #568 background imageLoading...
Page #568 background image
1-18
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-25303-03
Chapter 1 Configuring STP
Configuring Spanning-Tree Features
Beginning in privileged EXEC mode, follow these steps to configure a switch to become the root for the
specified VLAN. This procedure is optional.
To return to the default setting, use the no spanning-tree vlan vlan-id root global configuration
command.
Configuring a Secondary Root Switch
When you configure a switch as the secondary root, the switch priority is modified from the default value
(32768) to 28672. The switch is then likely to become the root switch for the specified VLAN if the
primary root switch fails. This is assuming that the other network switches use the default switch priority
of 32768 and therefore are unlikely to become the root switch.
You can execute this command on more than one switch to configure multiple backup root switches. Use
the same network diameter and hello-time values that you used when you configured the primary root
switch with the spanning-tree vlan vlan-id root primary global configuration command.
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
spanning-tree vlan vlan-id root primary
[diameter net-diameter [hello-time seconds]]
Configure a switch to become the root for the specified VLAN.
For vlan-id, you can specify a single VLAN identified by
VLAN ID number, a range of VLANs separated by a
hyphen, or a series of VLANs separated by a comma. The
range is 1 to 4094.
(Optional) For diameter net-diameter, specify the
maximum number of switches between any two end
stations. The range is 2 to 7.
(Optional) For hello-time seconds, specify the interval in
seconds between the generation of configuration messages
by the root switch. The range is 1 to 10; the default is 2.
Step 3
end Return to privileged EXEC mode.
Step 4
show spanning-tree detail Verify your entries.
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3560-X and is the answer not in the manual?

Cisco Catalyst 3560-X Specifications

General IconGeneral
Enclosure TypeRack-mountable - 1U
SubtypeGigabit Ethernet
Ports48 x 10/100/1000 + 4 x SFP
Flash Memory64 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Operating SystemCisco IOS
Device TypeSwitch
PerformanceSwitching capacity: 128 Gbps
Jumbo Frame SupportYes
Routing ProtocolRIP-1, RIP-2, EIGRP
Remote Management ProtocolSNMP 1, RMON 1, RMON 2, RMON 3, RMON 9, Telnet, SNMP 3, HTTP, HTTPS
FeaturesDHCP support, VLAN support, QoS, IPv6 support, Syslog
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3z, IEEE 802.1D, IEEE 802.1Q, IEEE 802.3ab, IEEE 802.1p, IEEE 802.3af, IEEE 802.3x, IEEE 802.3ad, IEEE 802.1w, IEEE 802.1x, IEEE 802.1s, IEEE 802.3ah, IEEE 802.1ag, IEEE 802.3at
StackingStackable
Security FeaturesSSH, RADIUS, TACACS+
ManagementCLI
Dimensions (H x W x D)17.5 in
Operating Temperature32 to 113 °F (0 to 45 °C)
Humidity10 - 95% (non-condensing)