1-3
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-25303-03
Chapter 1 Configuring System Message Logging and Smart Logging
Configuring System Message Logging
This example shows a partial switch system message for a stack master and a stack member (hostname
Switch-2):
00:00:46: %LINK-3-UPDOWN: Interface Port-channel1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/2, changed state to up
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/1, changed
state to down 2
*Mar 1 18:46:11: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
18:47:02: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
*Mar 1 18:48:50.483 UTC: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
00:00:46: %LINK-3-UPDOWN: Interface Port-channel1, changed state to up (Switch-2)
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/1, changed state to up (Switch-2)
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/2, changed state to up (Switch-2)
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
(Switch-2)
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/1, changed
state to down 2 (Switch-2)
Table 1-1 System Log Message Elements
Element Description
seq no: Stamps log messages with a sequence number only if the service sequence-numbers global
configuration command is configured.
For more information, see the “Enabling and Disabling Sequence Numbers in Log Messages”
section on page 1-8.
timestamp formats:
mm/dd hh:mm:ss
or
hh:mm:ss (short uptime)
or
d h (long uptime)
Date and time of the message or event. This information appears only if the service timestamps
log [datetime | log] global configuration command is configured.
For more information, see the “Enabling and Disabling Time Stamps on Log Messages” section
on page 1-8.
facility The facility to which the message refers (for example, SNMP, SYS, and so forth). For a list of
supported facilities, see Table 1-4 on page 1-14.
severity Single-digit code from 0 to 7 that is the severity of the message. For a description of the severity
levels, see Table 1-3 on page 1-10.
MNEMONIC Text string that uniquely describes the message.
description Text string containing detailed information about the event being reported.
hostname-n Hostname of a stack member and its switch number in the stack. Though the stack master is a stack
member, it does not append its hostname to system messages.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3560-X and is the answer not in the manual?

Cisco Catalyst 3560-X Specifications

General IconGeneral
Enclosure TypeRack-mountable - 1U
SubtypeGigabit Ethernet
Ports48 x 10/100/1000 + 4 x SFP
Flash Memory64 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Operating SystemCisco IOS
Device TypeSwitch
PerformanceSwitching capacity: 128 Gbps
Jumbo Frame SupportYes
Routing ProtocolRIP-1, RIP-2, EIGRP
Remote Management ProtocolSNMP 1, RMON 1, RMON 2, RMON 3, RMON 9, Telnet, SNMP 3, HTTP, HTTPS
FeaturesDHCP support, VLAN support, QoS, IPv6 support, Syslog
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3z, IEEE 802.1D, IEEE 802.1Q, IEEE 802.3ab, IEEE 802.1p, IEEE 802.3af, IEEE 802.3x, IEEE 802.3ad, IEEE 802.1w, IEEE 802.1x, IEEE 802.1s, IEEE 802.3ah, IEEE 802.1ag, IEEE 802.3at
StackingStackable
Security FeaturesSSH, RADIUS, TACACS+
ManagementCLI
Dimensions (H x W x D)17.5 in
Operating Temperature32 to 113 °F (0 to 45 °C)
Humidity10 - 95% (non-condensing)