Design Guide | iC7 Series Liquid-cooled System Modules
Table 81: Technical Data (continued)
Technical item or function Technical data
Protection rating IP00/NEMA/UL Open Type
Surrounding operating temperature Power units: -15 (no frost)…+60 °C (5...140 °F) at I
N
Control units: -15 (no frost)…+55 °C (5...131 °F) at I
N
Installation temperature -10...+70 °C (14...158°F)
Storage/transportation temperature -40…+70 °C (–40...158°F)
Glycol to be used in the coolant when temperature is un-
der 0 °C (32 °F). Freezing not allowed.
No coolant allowed in modules during storage/trans-
portation.
Relative humidity 5–96% RH, no condensation, no dripping water
Environmental conditions storage
(IEC 60721-3-1)
Climatic conditions: Class 1K21
Chemically active substances: Class 1C2
Biological conditions: Class 1B1
Mechanically active substances: Class 1S12
Environmental conditions trans-
portation (IEC 60721-3-2)
Climatic conditions: Class 2K11
Chemically active substances: Class 2C2
Biological conditions: Class 2B1
Mechanical conditions: Class 2M5
Mechanically active substances: Class 2S5
Environmental conditions operation
(IEC 60721-3-3)
Climatic conditions: Class 3K22
Chemically active substances: IEC 60721-3-3 Edition 3.0/
ISO 3223 Second Edition, class C4
Biological conditions: Class 3B1
Mechanically active substances: Class 3S6
Special climatic conditions (heat radiation): Class 3Z1
Pollution degree PD3
Ambient conditions
Altitude 0–4000 m (0–13000 ft) above sea level, when the net-
work is not corner grounded: Voltage class B5
0–3000 m (0–10000 ft) above sea level: Voltage class 07
without AFE supply
0–2000 m (0–6500 ft): Voltage class 07 with AFE supply
Above 1000 m (0–3000 ft): Derating of maximum sur-
rounding operating temperature by 0.5 °C per each 100
m (0.9 °F per each 330 ft) is required.
Danfoss Drives Oy © 2024.03 AJ475942178716en-000101 / 172K2848A | 219