Barcode Configuration | Code Collection
Reference Manual 93
Code Different When Scan Cap is Greater Than
Enter a minimum distance in mm which is required for the system to consider the
next code a different one.
The parameter set to 0 means the filter is disabled: when there is no scan gap all
the consecutive codes read will be considered as only one code. This defines the
gap between two packages.
Code Different when Code Position Gap is Greater Than
Enter a minimum distance in mm which is required for the system to consider the
next code a different one. This defines the gap between two bar codes.
This parameter is available only when the Code Combination parameter is set to
Code Collection and the scanner role is Master. If enabled, it allows transmitting all
codes belonging to the same programmed Slot (same symbology and content) but
read by different scanners (including the Master) in a single instance.
Scanner Role:
Master SYNCHRONIZED: The scanner is connected as a Master in a master/
slave synchronized configuration.
Slave SYNCHRONIZED: The scanner is connected as a Salve in a master/slave
synchronized configuration. (See note below.)
Other: This selection is for a stand-alone scanner.
The parameter set to 0 means the filter is disabled: when there is no code position
gap all the consecutive codes read will be considered as only one code.
Multi Filters
Select the check box to display the Multi-Filter Settings options.
Multi-Filter Settings
Contained Filter
Select the check box to reveal the Max Number of Different Characters field.
When checked, this filter attempts to eliminate false multiple reads by determining
if a short code read is "contained in" (is a sub-string of), another longer code read.
This condition implicates that the short code is probably a misread of the same
longer code and therefore should be ignored, (should not be considered as a
multiple read of a different code).