Replacing an Installed DX8210
Reference Manual 245
3. Label the cables attached to ETH1 and/or ETH2 so you can easily identify
where they were connected, then remove the cables.
4. Detach the existing scanner from its mounting bracket, leaving the bracket
attached to the mounting structure.
5. Attach the replacement scanner to the mounting bracket.
6. Reattach the power, I/O, ETH1 and/or ETH2 cables.
7. Apply power to the array.
8. Once the scanner has booted up and the READY LED lights solid green,
press and hold the RESTORE button until all of the LEDs turn on, indicating
that the parameters are being restored from the CBX510’s BM100 backup
module or SC5000 flash memory.
9. Release the RESTORE button.
Replacing a Master Scanner in an Array/Tunnel Using Restore
1. Remove power from the array.
2. Remove the power and I/O cables from the Master scanner being replaced.
3. Label the cables attached to ETH1 and/or ETH2 so you can easily identify
where they were connected, then remove the cables.
4. Detach the existing scanner from its mounting bracket, leaving the bracket
attached to the mounting structure.
5. Attach the replacement master scanner to the mounting bracket.
6. Reattach the power, I/O, ETH1 and/or ETH2 cables.
7. Apply power to the array.
8. Once the scanner has booted up and the READY LED lights solid green,
press and hold the RESTORE button until all of the LEDs turn on, indicating
that the parameters are being restored from the CBX510’s BM100 backup
module or SC5000 flash memory.
9. Release the RESTORE button.