Device Settings | Mounting
Reference Manual 167
Enter the scanner adjustment from Y axis in millimeters in the field provided. This
is used to make fine adjustments to the tested calibration. This is used during
dynamic calibration to fine tune the Y parameter.
For complete instructions on setting up your scanners using PackTrack, see the
DX8210 and DS8110 Reference Manuals, available at www.datalogic.com
.
PackTrack Calibration Coefficients
Calibration Item
1-9
These non-editable fields display the PackTrack calculations.
Use Built-in Calibration
Built-in Calibration (DX8210 only)
If Use Built-in Calibration is selected from the Calibration Method drop-down list.
The Scanner Orientation window appears. See the DX8210 Reference Manual
(Alternate Built-In Calibration for Top Mount), available at www.datalogic.com
, for
the complete procedure for setting up your barcode scanner with built-in
calibration.
Scanner Mounting Position
Select Top or Side from the drop-down list.
Scanner Orientation
Select Rotated Right, Forward, Rotated Left, or Backward from the drop down list.
At the time of publication, Built in calibration is not available for side mount scanners.
PackTrack calibration must be used. Top is the only available option with this manual
release.