Chapter 1 IntroductionMH300
1-7
Frame H–I
1. Remove RFI ON (frame H) or the screw of RFI-1 ON (frame I)
Screw Torque: 6–8 kg-cm / (5.2–6.9 lb-in.) / (0.59–0.78 Nm)
2. Remove the RFI jumper RFI-2 (frame I).