Chapter 11 Summary of Parameter Settings
MH300
11-9
Pr. Parameter Name Setting Range Default
00-31
Operation command
source
(HAND, LOCAL)
0: Digital keypad
1: External terminals
2: RS-485 communication
3: CANopen communication card
5: Communication card (CANopen card not included)
NOTE:
HOA (Hand-Off-Auto) function is valid only when you use with
MO function setting 41 and 56 or with KPC-CC01 (optional).
0
00-32
Digital keypad STOP
function
0: Disable STOP key
1: Enable STOP key
0
00-33 RPWM Mode Selection
0: Disabled
1: RPWM mode 1
2: RPWM mode 2
3: RPWM mode 3
0
00-34 RPWM Range 0.04.0 kHz 0.0
00-35
Auxiliary frequency
source
0: Master and auxiliary frequency function disabled
1: Inputs from digital keypad
2: Inputs from RS-485 communication
3: Inputs from analog input
4: Inputs from external UP / DOWN
(multi-function input terminals)
5: Pulse inputs without direction command
(refer to Pr.10-16)
6: CANopen communication card
8: Communication card
0
00-36
Master and auxiliary
frequency command
selection
0: Master + auxiliary frequency
1: Master - auxiliary frequency
2: Auxiliary - master frequency
0
00-47
Output phase order
selection
0: Standard
1: Reverse the rotation direction
0
00-48 Display filter time (current) 0.00165.535 sec. 0.100
00-49 Display filter time (keypad) 0.00165.535 sec. 0.100
00-50 Software version (date) Read only Read only